Home > Products > Electric Wire & Cable > UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
              UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
              • UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
              • UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
              • UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
              • UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901

              UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901

              ul1887 ul1901 24AWG 7/0.20mm Tinned Plated Copper FEP Wire ul 1887 ul 1901 PRODUCT DESCRIPTION:Rated temperature:200ºCRated voltage:600VAccording to:UL Subject758,UL1581,C22.2 Nickel plating or tin/bare copper conductorFEP InsulationPasses UL VW-1&CSA FT1 vertical flame testUniform insu......

              Send Inquiry

              Product Description

              ul1887 ul1901 24AWG 7/0.20mm Tinned Plated Copper FEP Wire ul 1887 ul 1901

               PRODUCT DESCRIPTION:
              ★Rated temperature:200ºC
              ★Rated voltage:600V
              ★According to:UL Subject758,UL1581,C22.2
              ★ Nickel plating or tin/bare copper conductor
              ★FEP Insulation
              ★Passes UL VW-1&CSA FT1 vertical flame test
              ★Uniform insulation thickness of wire to ensure 
                easy stripping and cutting
              ★For general purpose internal wiring of appliance
              AWGNO.of Cond
              (mm)
              Conductor resistance 20ºC
              (Ω/KM)
              Conductor Dia
              (mm)
              Insulation Thickness
              (mm)
              Overall Diameter
              (mm)
              Nom.Min.Nom.Tol.
              1037/0.423.54 2.94 0.35 0.33 3.60 ±0.15
              1237/0.3745.64 2.62 0.35 0.33 3.32 ±0.15
              1419/0.3618.96 1.85 0.35 0.33 2.60 ±0.10
              1619/0.28714.60 1.50 0.35 0.33 2.20 ±0.10
              1819/0.23523.20 1.18 0.35 0.33 1.90 ±0.10
              2019/0.1936.70 0.95 0.35 0.33 1.65 ±0.10
              2219/0.1559.40 0.76 0.35 0.33 1.45 ±0.10
              247/0.294.20 0.61 0.35 0.33 1.30 ±0.10
              267/0.16150.00 0.48 0.35 0.33 1.20 ±0.10
              281/0.32227.00 0.320 0.35 0.33 1.02 ±0.10
              301/0.254361.00 0.254 0.35 0.33 0.96 ±0.10
              UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901UL1887 UL1901 24AWG 7/0.20mm Tinned Plated Copper FEP Electric Wire UL 1887 UL 1901
               